Noise control for energy and industrial plants

Quiet energy.
Around the clock.

Acoustic enclosures, housings and noise barriers for battery storage, PV inverters, charging stations, transformers, power plants, combustion engines and recycling plants – designed for correct airflow and built with ABSORA's meta-acoustic metal HSA3.

For project developers, EPCs, building services engineers, grid and power plant operators, charging operators, waste companies and installers.

Aluminium acoustic enclosure around battery storage cabinets on a flat roof with PV modules
500+enclosure projects since 2015, all equipment types
up to −20 dB(A)noise reduction depending on version
A1HSA3 – non-combustible
100 Hz – 18 kHzfrom transformer hum to inverter whine
40–60 dayslead time for custom builds from order
Why noise control

Energy equipment runs when it should be quiet.

Batteries charge at night, charging hubs and depots run around the clock, transformers hum without pause. The night-time limit is usually decisive – and tones are rated more strictly than steady noise.

In Germany, TA Lärm applies; at night the loudest full hour between 10 pm and 6 am counts. Clearly audible tones – typical of inverters and transformers – add a penalty of 3 or 6 dB. Other countries have comparable rules.

Outdoor immission limits under German TA Lärm, in dB(A)
AreaDayNight
Commercial area6550
Urban area6345
Mixed, village, core area6045
General residential area5540
Purely residential area5035
Spa area, hospital4535
Listen: PV inverterwithout enclosure

This is the kind of tone that attracts the tonality penalty – original recording alternating every 3 seconds, first without, then with enclosure. Headphones recommended.

Recording: ABSORA GmbH. The loudness of a recording is not a measured value; what counts is the level calculation or measurement at the receiver.

Design

Quiet, without overheating the equipment.

Batteries, inverters and charging electronics derate in the heat. An enclosure must therefore not simply insulate – it has to guide the air correctly.

  1. Airflow from the manufacturerEach enclosure is designed for the unit's airflow, openings at max. 5 m/s – no flow noise, no heat build-up.
  2. No recirculationIntake at the bottom, exhaust at the top via HSA3 tubes – the unit does not draw in its own warm exhaust air.
  3. Stays accessibleDoors and clearances for maintenance, grid operators and fire services are planned from the start.
  4. Not a foreign bodyBuilt without a floor and without contact with the unit, RAL colour of your choice.
Who is behind it

Designed in Italy, built in Berlin.

eSilent is run by two partners with clear roles – you have one contact from enquiry to installation.

  1. Design – Silent Engineering, Osnago (IT)Acoustics, airflow (CFD) and structural design – your contact for quote and project.
  2. Manufacturing & installation – with ABSORA GmbH, BerlinDeveloper and patent holder of the meta-acoustic metal HSA3.
  3. Your enclosureDelivered as a pre-assembled kit and installed on request.
Technology

HSA3: noise control made of metal.

The lining made of ABSORA's meta-acoustic metal HSA3 absorbs exactly the low frequencies that are a nuisance with transformers and fans – with slim walls, low pressure drop and non-combustible to A1.

View from below into an acoustic enclosure with HSA3 tubes in roof and walls

Your project doesn't fit a standard box?

We design every enclosure individually – you usually receive the quote within a few hours.